Volkswagen Touran Service Manual: Battery Charger -VAS5906-
General Information
Battery Charger -VAS5906- |
WARNING
Risk of injury. Follow all Warnings and Safety
Precautions. Refer to
→ Chapter "Warnings and Safety Precautions". |
|
WARNING
Batteries that have a light yellow visual indicator
do not have to be tested or charged. Jump starting must
not be used! |
There is a risk of explosion during testing,
charging or jump starting. |
These batteries must be replaced. |
|
The Battery Charger -VAS5906- was developed especially for
charging the vehicle electrical system while the vehicle is on
display. |
It supplies for automatic charging of 3 - 300 Ah for starter
batteries. |
The 14.4 V maximum charging voltage is not exceeded. All
electrical consumers will be supported up to 30 A by the support
charging. |
After the battery is completely charged, the Battery Charger
-VAS5906- switches to maintenance charging for long-term
operation. |
The unit starts automatically and does not require any
adjustments. Only the charging terminals and the network cable
need to be connected. |
For more information. Refer to Battery Charger -VAS5906-
Operating Instructions. |
|
|
|
Note
If the battery is discharged by an electrical consumer
during maintenance charging, the Battery Charger -VAS5903-
automatically supplies the ...