Product Description
The Aquaplus system is a high-quality water-soluble basepaint system. It is based upon special PU dispersion technology for high-quality solid and metallic two-coat vehicle paintwork.
Properties:
Easy to process
Good stability under load
High covering capacity
Can be painted over with two-part HS clear coat
VOC compliant
  Note
After painting over with two-part HS clear coat it produces a high-gloss, weatherproof top coat.
Application Instructions
Base Surface
Suitable base surfaces:
Intact old paint
Primed and filled surfaces (two-part HS filler)
with One-Part Wash Primer -LVM 044 007 A2-/-LVM 044 171 A2- insulated base surfaces
with Two-Part Plastic Adhesive Filler -LKF 696 009 A2-/-LKF 696 040 A2- insulated base surfaces on plastic surfaces
See special instructions → Anchor.
   
Pre-treatment of base surfaces:
  Clean the factory or old paint or two-part HS filler thoroughly with Silicone Remover -LVM 020 000 A5- or Silicone Remover, Long -LVM 020 100 A5-.
  Aquaplus System (Solid and Metallic)
  Dry-sand with rotary sander and dust extraction, P400-500 grit.
  Aquaplus System (Solid and Metallic)
  Or "wet"-sand with P800-1000 sandpaper.
  Aquaplus System (Solid and Metallic)
  Use a suitable cleaning agent before reworking to ensure a clean and residue-free surface.
  Wipe off any residual silicone remover with a lint-free cloth, leaving no streaks.
Special Instructions
Sanded-through areas must be insulated with One-Part Wash Primer -LVM 044 007 A2-/-LVM 044 171 A2-. The sanded-through areas should not be larger than 5.0 cm in diameter.
When using the two-part HS filler, any bare areas must be insulated with Two-Part Wash Primer -LHV 043 000 A2- or One-Part Wash Primer -LVM 044 007 A2-/-LVM 044 171 A2-.
Processing
Mixing vessels:
Plastic containers or tin-coated cans painted on the inside
Strainers:
Filter watery base paint through water-tight, 125 mm strainers before working with cup systems.
Thinner:
Aquaplus Purified Water -LVW 010 000 A5- (according to ISO 3696)
Use an Aquaplus measuring stick.
An addition of 0 to 5 % Purified Water -LVW 010 000 A5- is sufficient at higher temperatures (>+25 C (77 F)) and a high relative humidity (> 60 %).
  Note
For safety reasons, do not store mixtures that contain both Microsilver, Extra -LWM 076 817 A2/A4- and Oxide Glaze -LWM 075 831 A1-. Pressure can build up in sealed containers!
Accumulated residue should be immediately disposed of properly. Refer to → Anchor.
  Aquaplus System (Solid and Metallic)
Application type "coat"
  Aquaplus System (Solid and Metallic)
  Processing viscosity at +20 C (68 F) material temperature is the mixing viscosity for "Compliant" and "HVLP".
  Aquaplus System (Solid and Metallic)
  Add 10 % thinner at +20 C (68 F) material temperature.
  Aquaplus System (Solid and Metallic)
  Set spray nozzle (see manufacturer's information): "Compliant" 1.2 to 1.3 mm.
  Set spray nozzle (see manufacturer's information): "HVLP" WSB/1.3 mm.
  Set spray pressure (see manufacturer's information): "Compliant" to 2.0 to 2.5 bar.
  Set atomizing pressure (see manufacturer's information): "HVLP" 0.7 bar.
  Aquaplus System (Solid and Metallic)
  An application includes: applying a thin spray application and then a normal spray application. For color shades with special effects, we recommend a "finishing application".
  Note
For less opaque colors, it may be necessary to apply additional spray applications after the corresponding ventilation time.
  Aquaplus System (Solid and Metallic)
Drying
  Aquaplus System (Solid and Metallic)
The ventilation time for clear coat application is at +20 C (68 F) room temperature for 20 minutes.
For smaller surfaces, the following make it possible to reduce the ventilation time:
The painted surfaces can be applied more quickly by blowing them with blower nozzles (hand blowers or with stationary devices).
Blowing with a spray gun is also possible after waiting at least five minutes.
For larger surfaces, the following make it possible to reduce the ventilation time:
The painted surfaces can be applied more quickly by using stationary blowing devices (such as ceiling systems), infrared radiators or oven drying.
Ceiling system 10 to 15 minutes
IR drying 3 to 5 minutes
Cooling time a minimum of 5 minutes
  Aquaplus System (Solid and Metallic)
Heated Drying at +60 C (140 F)
Combination booth at least 10 minutes including heating time
Drying-oven at least 5 minutes.
Cooling time a minimum of 5 minutes
  Note
The evaporating and drying times specified here depend on the temperature, humidity, air sink speed in the spray booth and the number of spray applications. However, you must wait for painted surface to be applied completely.
  Aquaplus System (Solid and Metallic)
Reworking
Can be painted over with:
Two-part HS clear coat from the Volkswagen original paint product line
Special Instructions
Touch-up system (for attaining an optically perfect color shade transition to the adjacent parts)
Preparation:
  Sand the filled areas (dry with P400-500 or with water-proof P800-1000 paper).
  Thoroughly sand the adjacent surfaces with a fine sanding pad.
  Clean the entire surface thoroughly with Silicone Remover -LVM 020 000 A5- to remove dust, sanding residue and other dirt.
  Wipe off any residual silicone remover with a lint-free cloth, leaving no streaks.
  Allow wet-sanded surfaces and cleaned surfaces to dry completely.
Touch-up system for metallic and solid color shades:
  Thoroughly cover the filled areas with water-based paint which has been prepared for spraying.
  Expand the scope of each subsequent spray application. This overlapping results in only one misted zone.
  Expand the run-off area and touch-up with reduced pressure.
  After an appropriate final ventilation time, paint over with two-part HS clear coat.
Using the Products
The spray devices should be suitable for use with water-soluble products; see manufacturer's information.
The mixing paints in this top coat series can only be used within the color tone formulas. When processing individual mixing paints on their own, major deviations from the information given in the application instructions are possible.
Cleaning the Tools
Rinse before and after using with Aquaplus Purified Water -LVW 010 000 A5-. Then rinse with Nitrocellulose Thinner -LVE 856 000 A3-.
Disposal
Collect liquid waste from water-soluble products and separate from liquid waste from conventional products. When mixing materials, disposal may no longer be possible, which is difficult and costly.
  Aquaplus System (Solid and Metallic)
Personal Protective Equipment:
Note the safety data sheets
Wear the personal protective equipment during application
Characteristics
  Aquaplus System (Solid and Metallic)
Flashpoint: above +23 C (73.4 F)
VOC value: 2004/42/IIB(d)(420)420 The EU limit for this product (product category IIB.b) in ready-to-use form is a maximum of 420 g/L volatile organic compounds. The VOC-value of this product in ready-to-use form is a maximum of 420 g/L.
 
     
Storage
The guaranteed shelf life for each product is:
24 months from date of manufacture for Water-Based Solid Mixed Paint -LWM 075 ...-.
24 months from date of manufacture for Water-Based Solid Base Paint -LUW/LWG 038 ...-.
24 months from date of manufacture for Water-Based Metallic Mixed Paint -LWM 076 ...-.
18/24 months from date of manufacture for Water-Based Metallic Base Paint -LMW/LWG 039 ...-
Use all of the products no later than the date indicated on the label and store in original container at +20 C (68 F).
  Aquaplus System (Solid and Metallic)
Storage Conditions
The optimal storage temperature is +20 C (68 F) (not to fall below +5 C (41 F)).
The preferred temperature is between +15 C (59 F) and +25 C (77 F).
For short-term storage (approximately 4 weeks), between +5 C (41 F) and +35 C (95 F) is acceptable.
  Aquaplus System (Solid and Metallic)
Two-Part HS Top Coat
Definition: Two-Part HS Solid Top Coat -L2K 073 ... ..- Two-Part HS Mixed Paint -L2K 074 ... ..- ...

Aquaplus System (Pearl Effect and Heliochrome)
Definition: Water-Based Pearl Effect Base Paint -LPW 040 ...- Water-Based Heliochrome Base Paint -LHW 046 ...- ...

Other materials:

Volkswagen Touran Owners Manual. Indicator lamps
First read and observe the introductory information and safety warnings  Lit up Possible cause Correction Engine management system malfunction (Electronic Power Control). The engine should be checked by a qualified works ...

Volkswagen Touran Owners Manual. Introduction
This chapter contains information on the following subjects:  → How to start the engine using jump leads   If the engine cannot be started because of a discharged vehicle battery, the battery can be connected to the battery of another vehicle to start the engine. Before using jump le ...

© 2016-2024 Copyright www.vwtouran.net | 0.0076